Home>mall>Tools, Industrial & Scientific
0Jaallatame

AAI ORIGINAL English Verison N1201SA N1201SA+ 34.375MHz-2.7GHz UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester

4.5
★★★★★
273
$109.99 /$134.19
  • *Name:

  • *Email:

  • *Phone:

  • *Quantity:

  • *Content:

  • Attachment:

    Supports JPG, JPEG, PNG, PDF, EXCEL, WORD, RAR, ZIP, 7z formats

$93.99 /$134.19

Bitannee Nagaa Mirkanaa'e

Kennaa Bilisummaa
Kennaa bilisummaa bitannoo hunda wajji
Ijaarsa Geessuu
Geessuu sadarkaa bilisummaa bitannoo $9.9 ol irratti
Ijaarsa Deebii
Deebiin kennaa guyyaa 40 olitti kennaa argateetti fudhata. Kennaa filatamaa deebii ykn jijjiiramaa hin taane. Kennaa kaardii kennaa elektronii wajjiin bitame jijjiiramaa qofa; deebiin hin fudhatamu.

Kennaa Bilisummaa

Baga Nagaan Dhufte Roymall, website kee kennaa department store gaarii bitachuuf. Deeggarsa kee guddaa nuu kennameef galatoomi. Kennaa bilisummaa bitannoo kee wajjiin kennina. Yeroo nuu wajji bitattu, kennaa gaarii argachuufi kennaa bilisummaa argattu. Kennaa filatamaa argachuuf website keenya daawwachuu fi bitannoo kee gochuu dandeessu.

Ijaarsa Geessuu

Kennaa kee guyyaa 2 olitti geessina. Yeroo guyyaa Shanbataa, Dilbataa ykn ayyaanaa bitatte, guyyaa 2 olitti geessina. Guyyaa 5-7 olitti geessina (Dilbataa hanga Jimaata) yeroo flight delay ykn sababa biraa hin jiru. Sababaa geessuu keenya addunyaa hunda keessatti, yeroo geessuu bakka keetti hunda.

1. Ijaarsa Deebii fi Jijjiiramaa

Kennaa qofa roymall.com irraa bitame fudhanna. Yoo bitatte distributor ykn retailer biraa, nuu hin deebifamtu. Kennaa bilisummaa ykn jijjiiramaa hin fudhatu. Kennaa kee deebisuuf, kan hin fayyadamne fi akka argatte ta'uu qaba. Akkasumas kan pakii jalqabaa keessatti ta'uu qaba.Yeroo deebii argatte, pakii kee post office ykn courier biraa dhiisi.Deebii ykn jijjiirama guyyaa 3-5 olitti xumurna. Deebiin kaardii bitannoo keessan irratti deebifama.Kennaa filatamaa, guddina filatamaa, halluu filatamaa ykn maxxansi filatamaa hin deebifamu.Yoo gargaarsa barbaaddu, nuu qunnamtii. service@roymall.com ykn Whatsapp: +8619359849471

2. Ijaarsa Deebii

Deebii guutuu ykn 100% store credit argattu. Deebiin kaardii bitannoo keessan irratti deebifama. Tajaajila geessuu fi kaffaltii hin deebifamu. Tajaajila geessuu dabalataa yeroo pakii dhiyaate hin deebifamu. Isin kaffaltii kana kaffaltu, nutis hin deebifnu, yoo bitannoo deebi'e nuu wajjiin.Yeroo kennaa deebii argine, email ergina. Deebii ykn jijjiirama keessan mirkanaa'uu ykn mirkanaa'uu diduu keessan beeksisna.Yoo rakkoo deebii qabdu, nuu qunnamtii. service@roymall.com ykn Whatsapp: +8619359849471
Description:
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration

The default boot into single-point measurement interface.

Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.



Startup and shutdown:
Hold down the CTRL key off press the power switch button.

The boot state, long press (2S above) the switch button, after the release, the instrument will shut down

The boot state, long press (2S above) the switch button, after the release, the instrument will shut down



Recommend the use:
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.

2, try to use good quality RF cable and connectors.

3, calibrated cable marked to the next may not need to calibrate and direct use.

4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.

5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.

6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis



Specification:
working currency: 140MHz~2700MHz

stepped frequency: 1kHz

Display: 2.4inch TFT

resolution: 320*240(QVGA)

battery: 2000mAH(7.4Wh)

power consumption: <1.5W

charge current: 400mA

charge port: USB

Auto power off can be set 5-60minutes



Measured parameters:
resistence reactance standing wave s11

resolution ratio: 4 number

frequency accuracy: about 5ppm

Connector: SMA-K

Measurement range:
impedance: 0.1~1000

standing wave: 1.000~65

s11(dB): 0dB~-60dB

Working temperature: 0~40 degree



Package included:
1 x Original N1201SA Antenna Analyzer Meter

1 x English User Manual

Description:
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration

The default boot into single-point measurement interface.

Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.



Startup and shutdown:
Hold down the CTRL key off press the power switch button.

The boot state, long press (2S above) the switch button, after the release, the instrument will shut down

The boot state, long press (2S above) the switch button, after the release, the instrument will shut down



Recommend the use:
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.

2, try to use good quality RF cable and connectors.

3, calibrated cable marked to the next may not need to calibrate and direct use.

4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.

5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.

6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis



Specification:
working currency: 140MHz~2700MHz

stepped frequency: 1kHz

Display: 2.4inch TFT

resolution: 320*240(QVGA)

battery: 2000mAH(7.4Wh)

power consumption: <1.5W

charge current: 400mA

charge port: USB

Auto power off can be set 5-60minutes



Measured parameters:
resistence reactance standing wave s11

resolution ratio: 4 number

frequency accuracy: about 5ppm

Connector: SMA-K

Measurement range:
impedance: 0.1~1000

standing wave: 1.000~65

s11(dB): 0dB~-60dB

Working temperature: 0~40 degree



Package included:
1 x Original N1201SA Antenna Analyzer Meter

1 x English User Manual

Gaaffii Koo Gaaffii (65)